FIW

Breakdown Voltage (BDV) values for FIW will vary depending upon which standard is used to calculate these values.

When using the magnet wire standards for FIW (IEC 60317-0-7 & 60317-56) the BDV is calculated using the minimum insulation increase per size. (min. insulation increase = min. OD including insulation – nominal bare wire dimension).

When using the transformer standard for FIW (IEC 61558-2-16) the BDV calculation mistakenly uses the minimum insulation increase divided in half, erroneously resulting in approximately half the BDV values as the magnet wire standards.

Therefore a new version of IEC 61558-2-16 (new version IEC 61558-1) will be released soon, correcting errors (like the BDV calculation described above) found in the previous version. One major difference: the new version will require the FIW to maintain stability for one minute longer than the magnet wire BDV standard calculation during peak voltage.

Рассчет пробивного напряжения согл. FIW стандарта IEC 60317-0-7 

Тест производился путем наматывания провода на стержень (цилиндр) согласно нормы IEC 60851-4.3.2. Минимальное пробивное напяжение рассчитывается для каждой спецификации FIW при помощи толщины изоляционного слоя и специфических значений V/мкм из таблицы ниже: 

 

Номинальный диаметр проводника

мм

Мин. специфическое пробивное напряжение

V/µm

больше

меньше и вкл.

при комнат.температуре

при 180°C

- -

0.100

81

56

0.100

0.355

76

53

0.355

0.500

70

49

0.500

1.000

53

37

1.000

1.600

47

33


Примечание: специфическое пробивное напряжение это коэфицент из измеренных значений и прироста лака (толщина изоляции).

 

FIW быстрый поиск

 

Для подбора правильного типа FIW

 

Введите номинальное сечение провода (в мм) и град FIW в вводные поля ниже для рассчета Длины, Веса и мин. пробивного напряжения (согл. IEC 60317-56) специфицированного провода FIW (строка 1),

 

Или введите номинальное сечение провода (в мм) и требуемое мин.Пробивное напряжение (по IEC 60317-56) для рассчета соответствующего града FIW (строка 2).

 

                                                  
  1. Номинальный диаметр [мм] Град
    Длина [км/кг]???Вес [кг/км]???Мин Пробивное напряжение [V]???

  2. Номинальный диаметр [мм] Мин Пробивное напряжение [V]
    Длина [км/кг]???Вес [кг/км]???Град???

Рассчитанное мин. Пробивное напряжение при 20 °C согласно стандарта FIW IEC 60317-56

Номинальный
диаметр
FIW3FIW4FIW5FIW6FIW7FIW8FIW9
 
минминминминминминмин
[мм][V][V][V][V][V][V][V]
 
0.0711701218732404293534663997452
0.0801782234934834617575168858019
0.0901944251136454779591370478181
0.1002106267339695265656178579153
0.1062052266039525244653678289120
0.1122128273640285320661279049196
0.1182128281241805548691682849652
0.1202280296443325700706884369804
0.1252280296443325700706884369804
0.13223563040456060807600912010640
0.14024323192471262327752927210792
0.150250833445016668883601003211704
0.160266034965168684085121018411856
0.170273636486232805698801170413528
0.180288838005624744892721109612920
0.190296438765776767695761147613376
0.200304040285928782897281162813528
0.2123268433263848436104881254014592
0.2203268433263848436104881254014592
0.2243268433263848436104881254014592
0.2363572478870689348116281390816188
0.2503648478870689348116281390816188
0.2653800501673729728120841444016796
0.2803800501673729728120841444016796
0.30040285320767610032123881474417100
0.31540285320767610032123881474417100
0.33043325624798010336126921504817404
0.33543325624798010336126921504817404
0.35043325624798010336126921504816030
0.35543325624798010336126921504816030
0.375420055307700102901246014630
0.40042005530770098701204014210
0.425448058808050102201239014560
0.450448058808050102201239014560
0.475469061609030119001477017640
0.5004690616090301190014770
0.530371049827155932811501
0.550376349827155932811501
0.560376349827155932811501
0.600397552477420959311766
0.630397552477420959311766
0.650424055657738991112084
0.670424055657738991112084
0.710424055657738991112084

жирный шрифт

=складской продукт

 

Пробивное напряжение согласно стандарта для трансформаторов IEC 61558-2-16

Напряжение указанное в стандарте IEC 61558 будет изменено на более высокие значения в следующей версии стандарта IEC 61558 (находится в разработке).

Номинальный
диаметр
FIW3FIW4FIW5FIW6FIW7FIW8FIW9
 
минминминминминминмин
[мм][V][V][V][V][V][V][V]
 
0.071756109214561820218425482912
0.080784117615681960235227443136
0.090840123216242016240828003192
0.100896134417922240268831363584
0.106901135218022253270331543604
0.112928137818292279273031803631
0.118954143119082385286233393816
0.1201007148419612438291533923869
0.1251007148419612438291533923869
0.1321034156420942624315436844214
0.1401087161721472677320737374267
0.1501140172323062889347240554638
0.1601193177623592942352541084691
0.1701246188227833419405546915327
0.1801299193525713207384344795115
0.1901325198826503313397546385300
0.2001378204127033366402846915353
0.2121484220029153631434650625777
0.2201484220029153631434650625777
0.2241484220029153631434650625777
0.2361643243832334028482356186413
0.2501643243832334028482356186413
0.2651723254433664187500958306652
0.2801723254433664187500958306652
0.3001829265034724293511559366758
0.3151829265034724293511559366758
0.3301935275635784399604260426864
0.3351789254833084067482755866346
0.3501935275635784399522160426864
0.3551789254833084067482755866346
0.375191126713577433750965856
0.400191126713430419049498709
0.425203427933553431250725831
0.450203427933553431250725831
0.475213231364141514561506909
0.50021323136414151456150
0.53017212479323839964755
0.55017212479357139964755
0.56017212479357139964755
0.60018132572333040894847
0.63018132572333040894847
0.65019242683344142004958
0.67019242683344142004958
0.71019242683344142004958

 

From 2018 onwards the following table will apply:

In future, IEC 61558-2-16 will refer to IEC 61558-1 and the table in IEC 61558-2-16 will be omitted.

Breakdown Voltage Calculation acc. to Transformer Standard IEC 61558-1, (not published yet)

 

U=OD - Cu∅ x V/µm x 10³ x 0.85    (at 180°C for 60 seconds)

Номинальный
диаметр
FIW3FIW4FIW5FIW6FIW7FIW8FIW9
 
minminminminminminmin
[мм][V][V][V][V][V][V][V]
 
0.0407149041428190423802856
0.04580910471618214226663189
0.05080910951618214226663189
0.05690412381761233229043475
0.063100012851904252331423760
0.0711000128519042523314237604379
0.0801047138020472713338040464712
0.0901142147621422808347541414780
0.1001238157123323094385646175379
0.1121261162223883154391946855451
0.1251352175725683379419050015811
0.1401442189227933694459554966397
0.1601577207230634055504660377028
0.1801712225333344415549665777659
0.2001802238835144640576668938019
0.2241937256837845001621774338650
0.2502162283841905541689382449596
0.2802253297343705766716385609956
0.31523883154455059477343874010136
0.35525683334473061277523892010316
0.400249932904582587371648455
0.45026663499479060817372
0.50027913665537370818788
0.56022332956424655356825
0.63023593114440356926982
0.71025163302459256817171
0.8002673352251266730
0.9002831374353476950
1.0002988393155357139
1.120274936185330
1.250280537035414
1.400288938155526
1.600300139555666

 

Настоящая версия стандарта для трнсформаторов  IEC 61558 задает более низкие значения для напряжения чем стандарт  IEC 60317-0-7 т.к. 

  • IEC 60317 использует прирост изоляции/толщину изоляции (внешний диаметр провода – номинальный диаметр без изоляции) для расчета напряжения в то время как стандарт IEC 61558 использует толщину изоляционного слоя (внешний диаметр – номин. Диаметр)/2, что в результате дает вдвое меньшие значения пробивного напряжения чем стандарт  IEC 60317-0-7.
  • Специфическое напряжение на 1 микрон дается в обоих стандартах для температуры 180°C, в то время как стандарт IEC 60317-0-7 также доп. дает значения при комнатной температуре. В действительности температура для SMPS (импульсивный стабилизатор напряжения) лежит где-то между этими двумя значениями.
  • Для расчета пробивного напряжения норма IEC 60317-0-7 берет за основу средний внешний диаметр провода в то время как норма  IEC 61558 калькулирует с макс. значением внешнего диаметра, что приводит к более высоким значениям напряжения в стандарте IEC 61558.

 

Различия в значениях пробивного напряжения должны быть разъяснены в следующем издании стандарта  IEC 61558.