FIW

Breakdown Voltage (BDV) values for FIW will vary depending upon which standard is used to calculate these values.

When using the magnet wire standards for FIW (IEC 60317-0-7 & 60317-56) the BDV is calculated using the minimum insulation increase per size. (min. insulation increase = min. OD including insulation – nominal bare wire dimension).

When using the transformer standard for FIW (IEC 61558-2-16) the BDV calculation mistakenly uses the minimum insulation increase divided in half, erroneously resulting in approximately half the BDV values as the magnet wire standards.

Therefore a new version of IEC 61558-2-16 (new version IEC 61558-1) will be released soon, correcting errors (like the BDV calculation described above) found in the previous version. One major difference: the new version will require the FIW to maintain stability for one minute longer than the magnet wire BDV standard calculation during peak voltage.

Obliczenie wytrzymałości dielektrycznej zognie z normą FIW IEC 60317-0-7

Wytrzymałość dielektryczna jest mierzona zgodnie z normą IEC 60851-4.3.2 metodą cylindryczną. Minimalne przebicie dla każdej żyły FIW jest liczone według przyrostu lakieru. Wartoś V/µm  jest podana w poniższej tabeli.  

 

Średnica

mm

Minimalne przebicie według specyfikacji

V/µm przyrost emalii

większa niż

do włącznie

w temperaturze pomieszczenia

W 180°C

- -

0.100

81

56

0.100

0.355

76

53

0.355

0.500

70

49

0.500

1.000

53

37

1.000

1.600

47

33


 Uwaga: Specyfikacja przebicia jest wyliczona z mierzonej wartości oraz przyrostu lakieru.

 

 

FIW Szybki wybór

 

Aby dokonać wyboru odpowiedniego przewodu FIW

proszę podać średnię (w mm) oraz przyrost emalii w poniższych polach. Aplikacja pozwala obliczyć: długość, wagę oraz minimalne przebicie (zgodnie z normą IEC 60317-56) dla poszczególnego typu FIW (kolumna 1),

lub proszę podać średnicę (w mm) i wymaganą minimalną wytrzymałość dielektryczną (zgodnie z IEC 60317-56), zostanie określony odpowiedni stopień emalii, oraz odpowiedni dobór drutu FIW (kolumna 2).

  1. Średnica nominalna Emalia
    Długość [km]???Waga [kg]???min. wytrzymałość dielektryczna???

  2. Średnica nominalna min. wytrzymałość dielektryczna
    Długość [km]???Waga [kg]???Emalia???

Obliczona wytrzymałość dielektryczna w temp. 20 °C zgodnie z FIW IEC 60317-56

Średnica nominalnaFIW3FIW4FIW5FIW6FIW7FIW8FIW9
 
minminminminminminmin
[mm][V][V][V][V][V][V][V]
 
0.0711701218732404293534663997452
0.0801782234934834617575168858019
0.0901944251136454779591370478181
0.1002106267339695265656178579153
0.1062052266039525244653678289120
0.1122128273640285320661279049196
0.1182128281241805548691682849652
0.1202280296443325700706884369804
0.1252280296443325700706884369804
0.13223563040456060807600912010640
0.14024323192471262327752927210792
0.150250833445016668883601003211704
0.160266034965168684085121018411856
0.170273636486232805698801170413528
0.180288838005624744892721109612920
0.190296438765776767695761147613376
0.200304040285928782897281162813528
0.2123268433263848436104881254014592
0.2203268433263848436104881254014592
0.2243268433263848436104881254014592
0.2363572478870689348116281390816188
0.2503648478870689348116281390816188
0.2653800501673729728120841444016796
0.2803800501673729728120841444016796
0.30040285320767610032123881474417100
0.31540285320767610032123881474417100
0.33043325624798010336126921504817404
0.33543325624798010336126921504817404
0.35043325624798010336126921504816030
0.35543325624798010336126921504816030
0.375420055307700102901246014630
0.40042005530770098701204014210
0.425448058808050102201239014560
0.450448058808050102201239014560
0.475469061609030119001477017640
0.5004690616090301190014770
0.530371049827155932811501
0.550376349827155932811501
0.560376349827155932811501
0.600397552477420959311766
0.630397552477420959311766
0.650424055657738991112084
0.670424055657738991112084
0.710424055657738991112084

pogrubione

=dostępne na magazynie

 

Obliczenie wytrzymałości dielektrycznej zgodnie z normą dla transformatorów IEC 61558-2-16

Wskazane parametry napięcia w normie IEC 61558 zostaną w zawyżone przy najbliższej aktualizacji normy.

Średnica nominalnaFIW3FIW4FIW5FIW6FIW7FIW8FIW9
 
minminminminminminmin
[mm][V][V][V][V][V][V][V]
 
0.071756109214561820218425482912
0.080784117615681960235227443136
0.090840123216242016240828003192
0.100896134417922240268831363584
0.106901135218022253270331543604
0.112928137818292279273031803631
0.118954143119082385286233393816
0.1201007148419612438291533923869
0.1251007148419612438291533923869
0.1321034156420942624315436844214
0.1401087161721472677320737374267
0.1501140172323062889347240554638
0.1601193177623592942352541084691
0.1701246188227833419405546915327
0.1801299193525713207384344795115
0.1901325198826503313397546385300
0.2001378204127033366402846915353
0.2121484220029153631434650625777
0.2201484220029153631434650625777
0.2241484220029153631434650625777
0.2361643243832334028482356186413
0.2501643243832334028482356186413
0.2651723254433664187500958306652
0.2801723254433664187500958306652
0.3001829265034724293511559366758
0.3151829265034724293511559366758
0.3301935275635784399604260426864
0.3351789254833084067482755866346
0.3501935275635784399522160426864
0.3551789254833084067482755866346
0.375191126713577433750965856
0.400191126713430419049498709
0.425203427933553431250725831
0.450203427933553431250725831
0.475213231364141514561506909
0.50021323136414151456150
0.53017212479323839964755
0.55017212479357139964755
0.56017212479357139964755
0.60018132572333040894847
0.63018132572333040894847
0.65019242683344142004958
0.67019242683344142004958
0.71019242683344142004958

 

From 2018 onwards the following table will apply:

In future, IEC 61558-2-16 will refer to IEC 61558-1 and the table in IEC 61558-2-16 will be omitted.

Breakdown Voltage Calculation acc. to Transformer Standard IEC 61558-1, (not published yet)

 

U=OD - Cu∅ x V/µm x 10³ x 0.85    (at 180°C for 60 seconds)

Średnica nominalnaFIW3FIW4FIW5FIW6FIW7FIW8FIW9
 
minminminminminminmin
[mm][V][V][V][V][V][V][V]
 
0.0407149041428190423802856
0.04580910471618214226663189
0.05080910951618214226663189
0.05690412381761233229043475
0.063100012851904252331423760
0.0711000128519042523314237604379
0.0801047138020472713338040464712
0.0901142147621422808347541414780
0.1001238157123323094385646175379
0.1121261162223883154391946855451
0.1251352175725683379419050015811
0.1401442189227933694459554966397
0.1601577207230634055504660377028
0.1801712225333344415549665777659
0.2001802238835144640576668938019
0.2241937256837845001621774338650
0.2502162283841905541689382449596
0.2802253297343705766716385609956
0.31523883154455059477343874010136
0.35525683334473061277523892010316
0.400249932904582587371648455
0.45026663499479060817372
0.50027913665537370818788
0.56022332956424655356825
0.63023593114440356926982
0.71025163302459256817171
0.8002673352251266730
0.9002831374353476950
1.0002988393155357139
1.120274936185330
1.250280537035414
1.400288938155526
1.600300139555666

Obecna wersja normy dla transformatorów IEC 61558 wskazuje zancząco zaniżone wartości a niżeli w IEC 60317-0-7, ponieważ
 

  • norma IEC 60317 oblicza przyrost emalii (średnica zwenetrzna – średnica żyły), podczas gdy norma IEC 61558 bazuje na obliczeniu siły emalii (średnica zewnętrzna – średnica żyły/2. W ten sposób wartości są o połowę mniejsze niż w normie
  • Specyfikacja wartości V/µ- odnosi się w normie IEC 60317-0-7 oraz IEC 61558 do temperatury 180 °C. W normie IEC 60317-0-7 dodatkowo do temperatury pokojowej. W rzeczywistości pożądana wartość SMPS (Switch Mode Power Supply) leży pomiędzy.
  • w normie IEC 60317-0-7 wytrzymałość dielektryczna jest podawana według przeciętnej średnicy, podczas gdy w normie  IEC 61558 jest brana pod uwagę maksymalna średnica zewnętrzna, w skutek czego norma IEC 61558 podaje nieco wyższe wartości.

Powyższe odstępstwa w wartościach wytrzymałości dieelktrycznej powinny zostać poprawione przy nowym wydaniu normy IEC 61558.