FIW

Breakdown Voltage (BDV) values for FIW will vary depending upon which standard is used to calculate these values.

When using the magnet wire standards for FIW (IEC 60317-0-7 & 60317-56) the BDV is calculated using the minimum insulation increase per size. (min. insulation increase = min. OD including insulation – nominal bare wire dimension).

When using the transformer standard for FIW (IEC 61558-2-16) the BDV calculation mistakenly uses the minimum insulation increase divided in half, erroneously resulting in approximately half the BDV values as the magnet wire standards.

Therefore a new version of IEC 61558-2-16 (new version IEC 61558-1) will be released soon, correcting errors (like the BDV calculation described above) found in the previous version. One major difference: the new version will require the FIW to maintain stability for one minute longer than the magnet wire BDV standard calculation during peak voltage.

Calculo del Voltaje de Ruptura de FIW de acuerdo al Estandard IEC 60317-0-7

La prueba de Voltaje de Ruptura es realizada por el método de cilindro de acuerdo a IEC 60851-4.3.2. El voltaje mínimo de ruptura tiene que ser calculado por cada alambre FIW específico usando el incremento del aislamiento y el específico valor de V/µm de la siguiente tabla.

 

Diámetro Nominal del Conductor

mm

Voltaje de ruptura minimo especifico

V/µm incremento

De:

A:

A temp. ambiente

a 180°C

- -

0.100

81

56

0.100

0.355

76

53

0.355

0.500

70

49

0.500

1.000

53

37

1.000

1.600

47

33


 NOTA:  El voltaje de ruptura específico es el resultado del cociente del valor medido y el incremento de esmalte.

 

Rápida Selección de FIW

Para una selección correcta del alambre FIW, seleccione Diámetro Nominal (in mm) y el grado de FIW en los campos correspondientes para calcular la Longitud, Peso y Voltaje Mínimo de Ruptura (de acuerdo a IEC 60317-56) del alambre FIW especificado ( línea 1 ).


De la misma manera, puede introducir el Diámetro Nominal (in mm) y el Voltaje mínimo de Ruptura requerido (de acuerdo a IEC 60317-56) para obtener el correspondiente grado de FIW del alambre FIW ( línea 2 ). 

 

  1. Diámetro Nominal [mm] Grado
    Longitud [km/kg]???Peso [kg/km]???min. Voltaje de Ruptura [V]???

  2. Diámetro Nominal [mm] min. Voltaje de Ruptura [V]
    Longitud [km/kg]???Peso [kg/km]???Grado???

Calculo del Voltaje de Ruptura Mínimo a 20°C de acuerdo al estandar de FIW IEC 60317-56

Diámetro
Nominal
FIW3FIW4FIW5FIW6FIW7FIW8FIW9
 
minminminminminminmin
[mm][V][V][V][V][V][V][V]
 
0.0711701218732404293534663997452
0.0801782234934834617575168858019
0.0901944251136454779591370478181
0.1002106267339695265656178579153
0.1062052266039525244653678289120
0.1122128273640285320661279049196
0.1182128281241805548691682849652
0.1202280296443325700706884369804
0.1252280296443325700706884369804
0.13223563040456060807600912010640
0.14024323192471262327752927210792
0.150250833445016668883601003211704
0.160266034965168684085121018411856
0.170273636486232805698801170413528
0.180288838005624744892721109612920
0.190296438765776767695761147613376
0.200304040285928782897281162813528
0.2123268433263848436104881254014592
0.2203268433263848436104881254014592
0.2243268433263848436104881254014592
0.2363572478870689348116281390816188
0.2503648478870689348116281390816188
0.2653800501673729728120841444016796
0.2803800501673729728120841444016796
0.30040285320767610032123881474417100
0.31540285320767610032123881474417100
0.33043325624798010336126921504817404
0.33543325624798010336126921504817404
0.35043325624798010336126921504816030
0.35543325624798010336126921504816030
0.375420055307700102901246014630
0.40042005530770098701204014210
0.425448058808050102201239014560
0.450448058808050102201239014560
0.475469061609030119001477017640
0.5004690616090301190014770
0.530371049827155932811501
0.550376349827155932811501
0.560376349827155932811501
0.600397552477420959311766
0.630397552477420959311766
0.650424055657738991112084
0.670424055657738991112084
0.710424055657738991112084

Negritas

=Producto se enuentra en existencia

 

Calculo del Voltaje de Ruptura de acuerdo a Transformador Estandar IEC 61558-2-16

Los voltajes dados en IEC 61558 serán modificados a valores más altos en la siguiente edición de IEC 61558.

Diámetro
Nominal
FIW3FIW4FIW5FIW6FIW7FIW8FIW9
 
minminminminminminmin
[mm][V][V][V][V][V][V][V]
 
0.071756109214561820218425482912
0.080784117615681960235227443136
0.090840123216242016240828003192
0.100896134417922240268831363584
0.106901135218022253270331543604
0.112928137818292279273031803631
0.118954143119082385286233393816
0.1201007148419612438291533923869
0.1251007148419612438291533923869
0.1321034156420942624315436844214
0.1401087161721472677320737374267
0.1501140172323062889347240554638
0.1601193177623592942352541084691
0.1701246188227833419405546915327
0.1801299193525713207384344795115
0.1901325198826503313397546385300
0.2001378204127033366402846915353
0.2121484220029153631434650625777
0.2201484220029153631434650625777
0.2241484220029153631434650625777
0.2361643243832334028482356186413
0.2501643243832334028482356186413
0.2651723254433664187500958306652
0.2801723254433664187500958306652
0.3001829265034724293511559366758
0.3151829265034724293511559366758
0.3301935275635784399604260426864
0.3351789254833084067482755866346
0.3501935275635784399522160426864
0.3551789254833084067482755866346
0.375191126713577433750965856
0.400191126713430419049498709
0.425203427933553431250725831
0.450203427933553431250725831
0.475213231364141514561506909
0.50021323136414151456150
0.53017212479323839964755
0.55017212479357139964755
0.56017212479357139964755
0.60018132572333040894847
0.63018132572333040894847
0.65019242683344142004958
0.67019242683344142004958
0.71019242683344142004958

 

From 2018 onwards the following table will apply:

In future, IEC 61558-2-16 will refer to IEC 61558-1 and the table in IEC 61558-2-16 will be omitted.

Breakdown Voltage Calculation acc. to Transformer Standard IEC 61558-1, (not published yet)

 

U=OD - Cu∅ x V/µm x 10³ x 0.85    (at 180°C for 60 seconds)

Diámetro
Nominal
FIW3FIW4FIW5FIW6FIW7FIW8FIW9
 
minminminminminminmin
[mm][V][V][V][V][V][V][V]
 
0.0407149041428190423802856
0.04580910471618214226663189
0.05080910951618214226663189
0.05690412381761233229043475
0.063100012851904252331423760
0.0711000128519042523314237604379
0.0801047138020472713338040464712
0.0901142147621422808347541414780
0.1001238157123323094385646175379
0.1121261162223883154391946855451
0.1251352175725683379419050015811
0.1401442189227933694459554966397
0.1601577207230634055504660377028
0.1801712225333344415549665777659
0.2001802238835144640576668938019
0.2241937256837845001621774338650
0.2502162283841905541689382449596
0.2802253297343705766716385609956
0.31523883154455059477343874010136
0.35525683334473061277523892010316
0.400249932904582587371648455
0.45026663499479060817372
0.50027913665537370818788
0.56022332956424655356825
0.63023593114440356926982
0.71025163302459256817171
0.8002673352251266730
0.9002831374353476950
1.0002988393155357139
1.120274936185330
1.250280537035414
1.400288938155526
1.600300139555666

 

La versión actual del Transformador Estandar IEC 61558 proporciona valores más bajos que IEC 60317-0-7 porque

  • IEC 60317 usa el incremento de aislante (diámetro exterior – diámetro del alambre desnudo) para el cálculo, mientras IEC 61558 usa como base el espesor del aislante (diámetro exterior – diámetro alambre desnudo)/2, el cual resulta en la mitad de los valores del voltaje de ruptura de IEC 60317-0-7.
  • El voltaje específico por micra es dado de acuerdo a IEC 60317-0-7 y IEC 61558 a 180 °C y de acuerdo a IEC 60317-0-7 también a temperatura ambiente. La temperatura necesaria de SMPS (Switch Mode Power Supply) se encuentra dentro de esos rangos.
  • Para el cálculo del Voltaje de Ruptura, IEC 60317-0-7 toma en cuenta el promedio del diámetro exterior, mientras que IEC 61558 toma en cuenta el máximo, lo cual resulta en valores ligeramente altos de IEC 61558.

 

Estas diferencias de valores de Voltaje de Ruptura deberán ser clarificados en la siguiente revisión de IEC 61558.