Dati tecnici del FIW norma IEC 60317-56

 

 Test parameter

 Test method

 Specification values

 for 0.30 mm FIW 6

 Typical values

 for 0.30 mm FIW 6

 Mechanical

        Elongation
        Tensile strength
        Springback


 IEC 60 851-3.1
 IEC 60 851-3.2
 IEC 60 851-3.4.1

 

 ≥ 23 %

 not specified

 not specified


 56 %
 310 N/mm²
 68°

 Solderability

        at 390 °C


 IEC 60 851-4.5

 

 ≤ 4 sec


 < 3.0 sec

 Thermal values

        Temperature index
        Heat shock

        Cut through


 IEC 60 172
 IEC 60 851-6.3.1.1

 IEC 60 851-6.4

 

 ≥ 180 °C

 ≥ 200 °C

 ≥ 245 °C


 192 °C
 220 °C/6 mm mandrel

 

 Breakdown voltage (cylinder)

        Volt
        V/µm    at room temperature
                    at 180°C
        (Volt per µm increase of

        insulation)



 IEC 60 851-5.4.3.2

 IEC 60 851-5.4.3.2

 

 min. 10 032 V

 min. 76 V/µm

 min. 53 V/µm

 


 >   15 kV
 > 100 V/µm ~
     
74 V/µm ~

 


 Per le altre caratteristiche vedere P180 scheda dati