FIW

Breakdown Voltage (BDV) values for FIW will vary depending upon which standard is used to calculate these values.

When using the magnet wire standards for FIW (IEC 60317-0-7 & 60317-56) the BDV is calculated using the minimum insulation increase per size. (min. insulation increase = min. OD including insulation – nominal bare wire dimension).

When using the transformer standard for FIW (IEC 61558-2-16) the BDV calculation mistakenly uses the minimum insulation increase divided in half, erroneously resulting in approximately half the BDV values as the magnet wire standards.

Therefore a new version of IEC 61558-2-16 (new version IEC 61558-1) will be released soon, correcting errors (like the BDV calculation described above) found in the previous version. One major difference: the new version will require the FIW to maintain stability for one minute longer than the magnet wire BDV standard calculation during peak voltage.

Calcul de la tension de claquage selon la Norme FIW IEC 60317-0-7

Le test est fait par un cylindre selon IEC 60851-4.3.2. La tension de claquage minimum doit être calculée pour chaque fil FIW utilisant l’augmentation par l’isolation et la valeur V/µm du tableau ci-dessous.

 

Nominal conductor diameter

mm

Minimum specific breakdown voltage

V/µm increase

over

up to and including

at room temperature

at 180°C

- -

0.100

81

56

0.100

0.355

76

53

0.355

0.500

70

49

0.500

1.000

53

37

1.000

1.600

47

33


 NOTE : La tension de claquage spécifique est le résultat du quotient de la valeur mesurée et de l’augmentation de l’émail.´

 

 

FIW Sélection rapide

Pour déterminer le bon fil FIW

Tapez le diamètre nominal (en mm) et le grade FIW dans les champs ci-dessous pour calculer la longueur, le poids et la tension de claquage minimum (selon IEC 60317-56) du fil FIW spécifié (ligne 1),

Ou tapez le diamètre nominal (en mm) et la tension de claquage minimum nécessaire (selon IEC 60317-56) pour avoir le Grade FIW du fil FIW correspondant (ligne 2).

  1. Diamétre nominal [mm] Grade
    Longueur [km/kg]???Poids [kg/km]???min. Tension de Claquage???

  2. Diamétre nominal [mm] min. Tension de Claquage
    Longueur [km/kg]???Poids [kg/km]???Grade???

Tension de claquage minimum calculée à 20°c selon Norme FIW IEC 60317-56

Nominal
Diamétre
FIW3FIW4FIW5FIW6FIW7FIW8FIW9
 
minminminminminminmin
[mm][V][V][V][V][V][V][V]
 
0.0711701218732404293534663997452
0.0801782234934834617575168858019
0.0901944251136454779591370478181
0.1002106267339695265656178579153
0.1062052266039525244653678289120
0.1122128273640285320661279049196
0.1182128281241805548691682849652
0.1202280296443325700706884369804
0.1252280296443325700706884369804
0.13223563040456060807600912010640
0.14024323192471262327752927210792
0.150250833445016668883601003211704
0.160266034965168684085121018411856
0.170273636486232805698801170413528
0.180288838005624744892721109612920
0.190296438765776767695761147613376
0.200304040285928782897281162813528
0.2123268433263848436104881254014592
0.2203268433263848436104881254014592
0.2243268433263848436104881254014592
0.2363572478870689348116281390816188
0.2503648478870689348116281390816188
0.2653800501673729728120841444016796
0.2803800501673729728120841444016796
0.30040285320767610032123881474417100
0.31540285320767610032123881474417100
0.33043325624798010336126921504817404
0.33543325624798010336126921504817404
0.35043325624798010336126921504816030
0.35543325624798010336126921504816030
0.375420055307700102901246014630
0.40042005530770098701204014210
0.425448058808050102201239014560
0.450448058808050102201239014560
0.475469061609030119001477017640
0.5004690616090301190014770
0.530371049827155932811501
0.550376349827155932811501
0.560376349827155932811501
0.600397552477420959311766
0.630397552477420959311766
0.650424055657738991112084
0.670424055657738991112084
0.710424055657738991112084

En gras

=article disponible sur stock

 

 

Calcul de la tension de claquage selon Norme Transformateur IEC 61558-2-16

Les tensions données dans la Norme IEC 61558 seront modifiées par de plus hautes valeurs dans la prochaine édition de la même norme.

Nominal
Diamétre
FIW3FIW4FIW5FIW6FIW7FIW8FIW9
 
minminminminminminmin
[mm][V][V][V][V][V][V][V]
 
0.071756109214561820218425482912
0.080784117615681960235227443136
0.090840123216242016240828003192
0.100896134417922240268831363584
0.106901135218022253270331543604
0.112928137818292279273031803631
0.118954143119082385286233393816
0.1201007148419612438291533923869
0.1251007148419612438291533923869
0.1321034156420942624315436844214
0.1401087161721472677320737374267
0.1501140172323062889347240554638
0.1601193177623592942352541084691
0.1701246188227833419405546915327
0.1801299193525713207384344795115
0.1901325198826503313397546385300
0.2001378204127033366402846915353
0.2121484220029153631434650625777
0.2201484220029153631434650625777
0.2241484220029153631434650625777
0.2361643243832334028482356186413
0.2501643243832334028482356186413
0.2651723254433664187500958306652
0.2801723254433664187500958306652
0.3001829265034724293511559366758
0.3151829265034724293511559366758
0.3301935275635784399604260426864
0.3351789254833084067482755866346
0.3501935275635784399522160426864
0.3551789254833084067482755866346
0.375191126713577433750965856
0.400191126713430419049498709
0.425203427933553431250725831
0.450203427933553431250725831
0.475213231364141514561506909
0.50021323136414151456150
0.53017212479323839964755
0.55017212479357139964755
0.56017212479357139964755
0.60018132572333040894847
0.63018132572333040894847
0.65019242683344142004958
0.67019242683344142004958
0.71019242683344142004958

 

From 2018 onwards the following table will apply:

In future, IEC 61558-2-16 will refer to IEC 61558-1 and the table in IEC 61558-2-16 will be omitted.

Breakdown Voltage Calculation acc. to Transformer Standard IEC 61558-1, (not published yet)

 

U=OD - Cu∅ x V/µm x 10³ x 0.85    (at 180°C for 60 seconds)

Nominal
Diamétre
FIW3FIW4FIW5FIW6FIW7FIW8FIW9
 
minminminminminminmin
[mm][V][V][V][V][V][V][V]
 
0.0407149041428190423802856
0.04580910471618214226663189
0.05080910951618214226663189
0.05690412381761233229043475
0.063100012851904252331423760
0.0711000128519042523314237604379
0.0801047138020472713338040464712
0.0901142147621422808347541414780
0.1001238157123323094385646175379
0.1121261162223883154391946855451
0.1251352175725683379419050015811
0.1401442189227933694459554966397
0.1601577207230634055504660377028
0.1801712225333344415549665777659
0.2001802238835144640576668938019
0.2241937256837845001621774338650
0.2502162283841905541689382449596
0.2802253297343705766716385609956
0.31523883154455059477343874010136
0.35525683334473061277523892010316
0.400249932904582587371648455
0.45026663499479060817372
0.50027913665537370818788
0.56022332956424655356825
0.63023593114440356926982
0.71025163302459256817171
0.8002673352251266730
0.9002831374353476950
1.0002988393155357139
1.120274936185330
1.250280537035414
1.400288938155526
1.600300139555666

La version actuelle de la Norme Transformateur IEC 61558 donne des valeurs bien plus basses que IEC 60317-0-7 parce que

  • IEC 60317 utilise l’augmentation de l’isolation (Diamètre extérieur – diamètre du fil nu) pour le calcul alors que IEC 61558 utilise l’épaisseur de l’isolation (Diamètre extérieur – diamètre du fil nu) / 2 comme base, ce qui donne la moitié des valeurs de tension de claquage de IEC 60317-0-7.
  • La tension spécifique par micron est donnée par IEC 60317-0-7 et IEC 61558 à 180°c et selon IEC 60317-0-7 également à température ambiante. La température nécessaire de SMPS (Switch Mode Power Supply) est quelque part entre les deux.
  • Pour le calcul de la tension de claquage, IEC 60317-0-7 prend le diamètre extérieur moyen alors que IEC 61558 prend le maximum, ce qui donne des valeurs légèrement supérieure à IEC 61558.

 

Ces différences de valeurs de tension de claquage devraient être clarifiées dans la prochaine version de IEC 61558.